Yaskawa Error Code A910 — [top]

The drive constantly monitors the DC bus voltage. If that voltage dips below the drive’s minimum operating threshold, it cannot guarantee proper output to the motor. This triggers .

is officially defined by Yaskawa as Main Circuit Undervoltage . This alarm triggers when the DC bus voltage inside the drive drops below the specified threshold. For a 200V class drive, this typically occurs below approximately 190 VDC (or around 150 VDC for single-phase models). For a 400V class drive, the undervoltage threshold is roughly 380 VDC to 400 VDC, depending on the model and load conditions. yaskawa error code a910

Always start with the simple things—measure your incoming voltage, tighten all connections, and disable momentary power loss ride-thru as a diagnostic step. Do not repeatedly reset the alarm without investigating; each undervoltage event stresses the drive’s front-end components. The drive constantly monitors the DC bus voltage

| Preventive Action | Benefit | | :--- | :--- | | Install a Line Reactor | Reduces voltage sags from upstream equipment and mitigates harmonics. | | Use a Three-Phase Line Monitor | Shuts down equipment when voltage drops below 10% of nominal, preventing drive stress. | | Replace Aging Drives | If capacitors are >7 years old in a hot environment, consider proactive replacement. | | Install a DC Bus Hold-Up Kit | Yaskawa offers external capacitor modules that extend ride-through time from 50ms to several seconds. | | Upgrade Wiring | One gauge size larger reduces voltage drop significantly for long runs (>50 feet). | Do not confuse A910 with these similar codes: is officially defined by Yaskawa as Main Circuit

By understanding the root causes and following the structured troubleshooting guide above, you can minimize downtime, avoid unnecessary drive replacements, and ensure your Yaskawa automation system runs reliably for years to come. Yaskawa’s technical documentation for your specific drive series (Technical Manual TM.V1000.01, for example) contains detailed timing charts and waveform examples for A910 detection. Always keep the latest manual available for your exact drive revision.

| Error Code | Name | Key Difference | | :--- | :--- | :--- | | | Main Circuit Overvoltage | DC bus voltage too high (often decel issues) | | A915 | Control Power Undervoltage | Internal 24V/12V logic supply failure | | A910 | Main Circuit Undervoltage | DC bus too low | | UV1 (fault) | Main Circuit Undervoltage (V1000) | Same as A910 but shown as fault, not alarm | | UV3 (fault) | Soft-Charge Circuit Fault | Specific failure of the inrush relay |

Introduction In the high-stakes world of industrial automation, downtime is costly. When a Yaskawa drive—whether from the V1000, J1000, U1000, GA700, or A1000 series—halts production with Error Code A910 , it signals a specific power-related fault. While this alarm can be alarming to operators, understanding its root causes is the first step toward rapid resolution.

yaskawa error code a910