Xy-w58cdt9-av7 Manual May 2026

A: Yes, but you must use external relays or solid-state isolators. Do not directly connect the trigger output of one to another without proper voltage matching.

| Terminal Label | Function | Notes | |----------------|------------------------------|--------------------------------------------| | | Power Input (+) | Connect to +12V or +24V DC. | | GND / DC- | Power Input (-) / Common | Ground. | | IN / Trig | Trigger/Signal Input | Pulse or continuous signal (high/low). | | NO | Normally Open Relay Contact | Closes when relay activates. | | COM | Relay Common Terminal | Connect load circuit here. | | NC | Normally Closed Relay Contact | Opens when relay activates. | xy-w58cdt9-av7 manual

| Mode | Name | Description | |------|-----------------------------|-----------------------------------------------------------------------------| | | Delay on Pull-up (On-delay) | Relay activates after set time once trigger is applied. | | P2 | Interval on Pull-up | Relay activates immediately, deactivates after set time. | | P3 | One-shot off | Trigger starts timer, relay turns off after delay (if initially on). | | P4 | Cyclic On First | Relay ON for time T1, OFF for time T2, repeats until stopped. | | P5 | Cyclic Off First | Relay OFF for time T1, ON for time T2, repeats. | | P6 | Triggered pulse (rising) | Short trigger pulse produces a fixed output pulse. | | P7 | Latching with delay | First trigger delays, second trigger resets. | | P8 | Infinite hold | Trigger toggles relay on; timer resets. | | P9 | Countdown + reset | Starts countdown; resetting restarts timer from original set value. | A: Yes, but you must use external relays